Abstract:
The aim of this study was to perform a realistic visualization of the auditory and vestibular system using volume data sets from high-resolution computed tomography (HR-CT) and high-resolution magnetic resonance imaging (HR-MRI). In 10 patients with conductive and/or sensorineural hearing loss, vertigo and tinnitus, HR-CT and HR-MRI of the petrous bone were performed consecutively. CT was performed with a 16-slice computed tomography scanner using a high spatial resolution. MRI was perfomed with...     »