The OPTION (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator Patients Without Pacing Indications) trial sought to compare long-term rates of inappropriate shocks, mortality, and morbidity between dual-chamber and single-chamber settings in implantable cardioverter-defibrillators (ICDs) patients.The use of dual-chamber ICDs potentially allows better discrimination of supraventricular arrhythmias and thereby reduces inappropriate shocks. However, it may lead to detrimental ventricular pacing.This prospective multicenter, single-blinded trial enrolled 462 patients with de novo primary or secondary prevention indications for ICD placement and with left ventricular ejection fractions<=40% despite optimal tolerated pharmacotherapy. All patients received atrial leads and dual-chamber defibrillators that were randomized to be programmed either with dual-chamber or single-chamber settings. In the dual-chamber setting arm, the PARAD+ algorithm, which differentiates supraventricular from ventricular arrhythmias, and SafeR mode, to minimize ventricular pacing, were activated. In the single-chamber setting arm, the acceleration, stability, and long cycle search discrimination criteria were activated, and pacing was set to VVI 40 beats/min. Ventricular tachycardia detection was required at rates between 170 and 200 beats/min, and ventricular fibrillation detection was activated above 200 beats/min.During a follow-up period of 27 months, the time to the first inappropriate shock was significantly longer in the dual-chamber setting arm (p = 0.012, log-rank test), and 4.3% of patients in the dual-chamber setting group compared with 10.3% in the single-chamber setting group experienced inappropriate shocks (p = 0.015). Rates of all-cause death or cardiovascular hospitalization were 20% for the dual-chamber setting group and 22.4% for the single-chamber setting group and satisfied the pre-defined margin for equivalence (p< 0.001).Therapy with dual-chamber settings for ICD discrimination combined with algorithms for minimizing ventricular pacing was associated with reduced risk for inappropriate shock compared with single-chamber settings, without increases in mortality and morbidity. (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator [ICD] Patients Without Pacing Indications [OPTION]; NCT00729703). 
Zeitschriftentitel:
JACC Heart Fail 
Jahr:
2014 
Band / Volume:
Heft / Issue:
Seitenangaben Beitrag:
611-9 
Sprache:
eng 
Print-ISSN:
2213-1779 
TUM Einrichtung:
Klinik für Herz- und Kreislauferkrankungen