Prediction of extubation failure in medical intensive care unit patients.
Abstract:
The purpose of this study was to evaluate prediction factors for extubation failure (need for reintubation within 48 hours) in medical intensive care unit patients.Sixty-one patients extubated after mechanical ventilation for more than 48 hours were included in the study. A retrospective analysis of medical records and a prospectively maintained database on respiratory parameters was conducted.Low serum anion gap (P = .001), low serum anion gap corrected for serum albumin (P = .010), and low art...     »