Benutzer: Gast  Login
Dokumenttyp:
Comparative Study; Journal Article
Autor(en):
Mißlbeck, M; Kneschaurek, P
Titel:
Comparison between Acuros XB and Brainlab Monte Carlo algorithms for photon dose calculation.
Abstract:
The Acuros® XB dose calculation algorithm by Varian and the Monte Carlo algorithm XVMC by Brainlab were compared with each other and with the well-established AAA algorithm, which is also from Varian.First, square fields to two different artificial phantoms were applied: (1) a "slab phantom" with a 3 cm water layer, followed by a 2 cm bone layer, a 7 cm lung layer, and another 18 cm water layer and (2) a "lung phantom" with water surrounding an eccentric lung block. For the slab phantom, depth-d...     »
Zeitschriftentitel:
Strahlenther Onkol
Jahr:
2012
Band / Volume:
188
Heft / Issue:
7
Seitenangaben Beitrag:
599-605
Sprache:
eng
Volltext / DOI:
doi:10.1007/s00066-012-0100-9
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/22526227
Print-ISSN:
0179-7158
TUM Einrichtung:
Klinik und Poliklinik für RadioOnkologie und Strahlentherapie
 BibTeX